This command has no effect on HP c3000 OA boards that are hardware revision level C0 and
o
later. Hardware revision is found using the SHOW OA INFO command.
•
Access level/Bay level:
OA Administrator
•
Restrictions:
None
Example
OA-0018FE27577F> SHOW OA USB
Onboard Administrator USB setting = FRONT
SHOW POWER
•
Command:
SHOW POWER
•
Description:
Displays the current power configuration
•
Access level/Bay level:
All
•
Restrictions:
None
Example
OA-0018FE27577F> SHOW POWER
Power Mode: Not Redundant
Dynamic Power: Enabled
Set Power Limit: Not Set
Power Capacity:
Power Available:
Power Allocated:
Present Power:
Power Limit:
SHOW SYSLOG
•
Command:
SHOW SYSLOG {SERVER <bay number> | ENCLOSURE | OA <bay number> |
SETTINGS}
•
Description:
Displays the syslog of the enclosure with 22 lines per screen. To quit the command, enter q. Any
other key shows the next screen, if there is more information to display.
•
Access level/Bay level:
Bay specific
All
3600 Watts DC
2685 Watts DC
915 Watts DC
476 Watts AC
4378 Watts AC
Enclosure management commands 90