Enclosure Dynamic Power Cap Commands; Set Enclosure Power_Cap; Set Enclosure Power_Cap_Bays_To_Exclude - HP Xw460c - ProLiant - Blade Workstation User Manual

Hp bladesystem onboard administrator command line interface user guide version 2.60
Hide thumbs Also See for Xw460c - ProLiant - Blade Workstation:
Table of Contents

Advertisement

Enclosure Dynamic Power Cap commands

SET ENCLOSURE POWER_CAP

Command:
SET ENCLOSURE POWER_CAP [< number> | OFF ]
Description:
Sets the Enclosure Dynamic Power Cap in watts AC. OFF disables Enclosure Dynamic Power Cap.
Access level/Bay level:
OA administrator, OA operator
Restrictions:
A redundant Onboard Administrator is required.
o
A redundant power configuration is required.
o
The Power Cap must be in the range displayed by the command SHOW ENCLOSURE
o
POWER_CAP.
In scripts, if both SET POWER LIMIT and SET ENCLOSURE POWER_CAP are set to non-zero
o
values, whichever command is used last takes precedence.
SET ENCLOSURE
POWER_CAP_BAYS_TO_EXCLUDE
Command:
SET ENCLOSURE POWER_CAP_BAYS_TO_EXCLUDE [NONE | <bay number> {[ , | - ]
<bay number>}]
Description:
Specifies bays to omit from Enclosure Dynamic Power Cap. Blades in omitted bays are treated as
unmanaged components of the system: They receive a maximum power allocation even when the
power is not being consumed, raising the minimum Enclosure Dynamic Power Cap value that can be
applied to the enclosure. Any blades in bays not specified are managed.
If you have previously specified bays to exclude, using this command again replaces that
specification rather than augmenting it.
Access level/Bay level:
OA administrator, OA operator
Restriction:
You can exclude no more than one fourth of the bays.
Enclosure Dynamic Power Cap commands 124

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bladesystem onboard administrator

Table of Contents