PDG-DXL2000 Expand Serial Command Functional Specifications

8.10.3 CF_AUTOSETUPPCADJ Command

Command
"CF_AUTOSETUPPCADJ_%1"[CR]
"ON" ------------------- Set Auto PC ADJ. function to ON
%1
"OFF" ------------------ Set Auto PC ADJ. function to OFF
Set/Cancel Auto PC adj. function
This command is available in normal Power ON status.
Details
Note) It is unable to set both PC ADJ. and Input search to OFF.
If projector receives Auto PC ADJ. OFF command while Input search is OFF, it
returns error code "101".
Acceptable
Response
Unacceptable

8.10.4 CF_INPUTSEARCH Command

Command
"CF_INPUTSEARCH_%1"[CR]
"OFF" ------------------------- Set Input search operation to OFF
%1
"ON1" ------------------------- Set Input search operation to On1
"ON2" ------------------------- Set Input search operation to On2
Set Input search operation mode.
The status set by this command is stored in EEPROM and its setting is effective
after ALL is OFF
Details
This command is available in normal Power ON status.
Note) It is unable to set both PC ADJ. and Input search to OFF.
If projector receives Input search OFF command while Auto PC ADJ. is OFF, it
returns error code "101".
Acceptable
Response
Unacceptable

8.10.5 CF_AUTOSETUP Command

Command
"CF_AUTOSETUP_%1"[CR]
%1
"START" ------------------- Execute Auto Setup
Execute Auto Setup
Details
Note) CF commands does not execute while Auto setup is in process. If the
command is sent during this, projector returns error code "302"
Acceptable
Response
Unacceptable

8.10.6 CF_3D SET Command

Command
"CF_3DSET_%1"[CR]
"ON" ------------------- Select ON
%1
"OFF" ------------------ Select OFF
"NVIDIA"--------------- Select NVIDIA 3D VISION
Setup 3D function.
The status set by this command is stored in EEPROM and its setting is effective
Details
after ALL is OFF.
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
35/72