Cf_Rcode Command; Cf_Keydis Command; Cf_Pjpincode Command - Sanyo PDG-DXL2000 - 2000 Lumens Specifications

Expand serial command functional specifications
Hide thumbs Also See for PDG-DXL2000 - 2000 Lumens:
Table of Contents

Advertisement

PDG-DXL2000 Expand Serial Command Functional Specifications

8.10.23 CF_RCODE Command

Command
"CF_RCODE_%1"[CR]
"001" --------------------------- Select Code1
"002" --------------------------- Select Code2
%1
"UP" --------------- The same operation as pressing Up key or Left key
"DN" --------------The same operation as pressing Down key or Right key
Select Code of Remote Control
The status set by this command is stored in EEPROM and its setting is effective
Details
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable

8.10.24 CF_KEYDIS Command

Command
"CF_KEYDIS_%1"[CR]
"NONE" ----------------------- RC & Projector keys are valid (All are valid)
%1
"RC" ---------------------------- RC keys are invalid
"KEY" -------------------------- Projector keys are invalid
(This command is available to models with top panel buttons only.)
Details
Disable RC/Projector keys
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable

8.10.25 CF_PJPINCODE Command

Command
"CF_PJPINCODE_%1"[CR]
%1
"0000" – "9999" ---------Set PJ PIN CODE directly
Set PJ PIN CODE to release PJ LOCK.
PIN CODE cannot be changed by this command.
-When PJ LOCK is in operation
PIN CODE is correct ------------------------- Command is valid (Acceptable)
PIN CODE is incorrect ----------------------- Command is invalid(Error Code"102")
PIN CODE is out of %1 range ------------- Command is invalid (Error Code "? ")
Details
-When PJ LOCK is not in operation
PIN CODE is within %1 range ---------------- Command is valid (Acceptable)
PIN CODE is out of %1 range ---------------- Command is invalid (Error Code "? ")
This command is valid during a dialog "PJ PIN CODE" is displayed after Power On
and Count down.
Also when PJ LOCK setting is "On1", it is necessary to transmit this command
every time lamp turns on.
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
41/72

Advertisement

Table of Contents
loading

Table of Contents