PLC-WL2500 / WL2501/ WL2503 Expand Serial Command Functional Specifications
8.10.3 CF_AUTOSETUPPCADJ Command
Command
"CF_AUTOSETUPPCADJ_%1"[CR]
"ON" ------------------- Set Auto PC ADJ. function to ON
%1
"OFF" ------------------ Set Auto PC ADJ. function to OFF
Set/Cancel Auto PC adj. function
This command is available in normal Power ON status.
Details
Note) It is unable to set both PC ADJ. and Input search to OFF.
If projector receives Auto PC ADJ. OFF command while Input search is OFF, it
returns error code "101".
Acceptable
Response
Unacceptable
8.10.4 CF_INPUTSEARCH Command
Command
"CF_INPUTSEARCH_%1"[CR]
"OFF" ------------------------- Set Input search operation to OFF
%1
"ON1" ------------------------- Set Input search operation to On1
"ON2" ------------------------- Set Input search operation to On2
Set Input search operation mode.
The status set by this command is stored in EEPROM and its setting is effective
after ALL is OFF
Details
This command is available in normal Power ON status.
Note) It is unable to set both PC ADJ. and Input search to OFF.
If projector receives Input search OFF command while Auto PC ADJ. is OFF, it
returns error code "101".
Acceptable
Response
Unacceptable
8.10.5 CF_AUTOSETUP
Command
"CF_AUTOSETUP_%1"[CR]
%1
"START" ------------------- Execute Auto Setup
Execute Auto Setup
Details
Note) CF commands does not execute while Auto setup is in process. If the
command is sent during this, projector returns error code "302"
Acceptable
Response
Unacceptable
8.10.6 CF_BACKGND Command
Command
"CF_BACKGND_%1" [CR]
"BLUE" -------------------- Select Blue Back
"USER" ------------------- Select User
%1
"BLACK" ------------------ Select Black Back
"UP" ---------- Switch forward (Blue Back→User→Black Back→Blue Back)
"DN" --------- Switch backward (Blue Back→Black Back→User→Blue Back)
Set Screen status for no signal.(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and the setting remains
even after the power is turned to ALL OFF status.
Details
*When ÿ
Capture non-practice.
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
1="USER" is received, error code "101" is returned, in the case of
"000" [CR]
"Error Code" [CR]