Functional Execution Command; Format; Transfer Example; Operation Requirements - Sanyo PDG-DXL2000 - 2000 Lumens Specifications

Expand serial command functional specifications
Hide thumbs Also See for PDG-DXL2000 - 2000 Lumens:
Table of Contents

Advertisement

PDG-DXL2000 Expand Serial Command Functional Specifications

8. Functional Execution Command

8.1 Format

1.
PC issues commands in format as below:
Pattern1 : "CF_COMMAND" [CR]
Pattern2 : "CF_COMMAND_"%1 [CR]
2.
The projector decodes the received command and when it is ready to receive the next
command, it returns the response.
"000" [CR] : (0x06, 0x0D) When receiving Functional Execution Command
"nnn" [CR] : Except "000" , when it is unable to execute command by any specific reason.
See Error Code Table for details
3.
When the received data cannot be decoded, the projector returns "?" [CR]

8.2 Transfer Example

When setting projector's total dots to 1344 by Expand Serial Command
PC → PJ: "CF_TDOTS_1344" [CR]
PC ← PJ: "000"[CR] - - - - - - - - - - - Acceptable

8.3 Operation Requirements

1) Functional Execution Command is limited when the projector status is as below.
However, Status Read Command is effective even under these conditions.
Projector Status
In Standby status
Countdown in process
Cooling down in process
Cooling down in process due to Abnormal
Temperature
Abnormal Temperature
Power Failure
(For 60 seconds after Power Failure occurred)
Power Save / Cooling down in process
Power Save in process
Note:) When the projector receives the other command in this above status, it returns
error code to show the status.
When the projector receives the following functional execution commands, OSD
menu is closed except for pop-up menu
2) Functional Execution Commands are invalid when Eco mode is selected in Standby mode of
Setting menu and projector is in standby
CF_ : Header
COMMAND : Character line
%1 : Parameter (Character line)
_ : Space (To separate COMMAND and Parameter)
16/72
Available Functional Execution Command
C00: POWER ON only
C00: POWER ON
(Terminates Countdown)
C01: POWER OFF
C02: POWER OFF
(Terminates Countdown)
N/A
N/A
N/A
N/A
N/A
C00: POWER ON
C01: POWER OFF

Advertisement