Health Monitoring Diagnostics - Cisco AJ732A - MDS 9134 Fabric Switch Configuration Manual

Cisco nexus 5000 series switch cli software configuration guide, nx-os 4.0(1a)n1 (ol-16597-01, january 2009)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

Information About Online Diagnostics
S e n d f e e d b a c k t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m
Table 24-1
Diagnostic
USB Flash
PCIe
OBFL
NVRAM
Voltage
GPIO
In band port
Management port
Memory
Bootup diagnostics also include a set of tests that are common with health monitoring diagnostics. The
bootup and health monitoring diagnostics are described in
Bootup diagnostics log any failures to the onboard failure logging (OBFL) system. Failures also trigger
an LED display to indicate diagnostic test states (on, off, pass, or fail).
You can configure Cisco Nexus 5000 Series switches to either bypass the bootup diagnostics, or run the
complete set of bootup diagnostics. See the

Health Monitoring Diagnostics

Health monitoring diagnostics provide information about the health of the switch. They detect runtime
hardware errors, memory errors, software faults, and resource exhaustion.
Health monitoring diagnostics are nondisruptive and run in the background to ensure the health of a
switch that is processing live network traffic.
Table 24-2
Table 24-2
Diagnostic
LED
Power Supply
Temperature Sensor
Test Fan
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
24-2
Bootup Diagnostics
Description
Verifies the integrity of the USB flash device.
Tests PCI express (PCIe) access.
Verifies the integrity of the onboard failure logging flash.
Verifies the integrity of the NVRAM.
Verifies that the voltage levels are within the correct
range.
Tests the general purpose I/O (GPIO) components.
Tests connectivity of the inband port to the supervisor.
Tests the management port.
Verifies the integrity of the DRAM.
describes the health monitoring diagnostics for the switch.
Health Monitoring Diagnostics Tests
Description
Monitors port and system status LEDs.
Monitors the power supply health state.
Monitors temperature sensor readings.
Monitors fan speed and fan control.
Chapter 24
Table
24-3.
"Configuring Online Diagnostics" section on page
Configuring Online Diagnostics
24-4.
OL-16597-01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents