Cisco AJ732A - MDS 9134 Fabric Switch Configuration Manual page 438

Cisco nexus 5000 series switch cli software configuration guide, nx-os 4.0(1a)n1 (ol-16597-01, january 2009)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

Information About Fibre Channel Interfaces
S e n d f e e d b a c k t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m
Only some of the reason codes are listed in
Note
If the administrative state is up and the operational state is down, the reason code differs based on the
nonoperational reason code.
Table 32-4
Reason Code (long version)
Link failure or not connected
SFP not present
Initializing
Reconfigure fabric in progress The fabric is currently being reconfigured.
Offline
Inactive
Hardware failure
Error disabled
Isolation because limit of
active port channels is
exceeded.
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
32-6
Table 32-4
describes the reason codes for nonoperational states.
Reason Codes for Nonoperational States
Description
The physical layer link is not operational.
The small form-factor pluggable (SFP) hardware is not
plugged in.
The physical layer link is operational and the protocol
initialization is in progress.
The switch software waits for the specified R_A_TOV
time before retrying initialization.
The interface VSAN is deleted or is in a suspended
state.
To make the interface operational, assign that port to a
configured and active VSAN.
A hardware failure is detected.
Error conditions require administrative attention.
Interfaces may be error-disabled for various reasons.
For example:
Configuration failure.
Incompatible buffer-to-buffer credit configuration.
To make the interface operational, you must first fix the
error conditions causing this state and then
administratively shut down or enable the interface.
The interface is isolated because the switch is already
configured with the maximum number of active SAN
port channels.
Chapter 32
Table
32-4.
Configuring Fibre Channel Interfaces
Applicable
Modes
All
All
OL-16597-01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents