Verifying San Port Channel Configuration - Cisco AJ732A - MDS 9134 Fabric Switch Configuration Manual

Cisco nexus 5000 series switch cli software configuration guide, nx-os 4.0(1a)n1 (ol-16597-01, january 2009)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

Chapter 36
Configuring SAN Port Channels
S e n d f e e d b a c k t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m

Verifying SAN Port Channel Configuration

You can view specific information about existing SAN port channels at any time from EXEC mode. The
following show commands provide further details on existing SAN port channels.
The show san-port-channel summary command displays a summary of SAN port channels within the
switch. A one-line summary of each SAN port channel provides the administrative state, the operational
state, the number of attached and active interfaces (up), and the first operational port (FOP), which is the
primary operational interface selected in the SAN port channel to carry control-plane traffic (no
load-balancing). The FOP is the first port that comes up in a SAN port channel and can change if the
port goes down. The FOP is also identified by an asterisk ( * ).
To display VSAN configuration information, perform one of the following tasks:
Command
switch# show san-port-channel summary |
database | consistency [ details ] |
usage | compatibility-parameters
switch# show san-port-channel database
interface san-port-channel
channel-number
switch# show interface fc slot/port
The following example shows how to display a summary of SAN port channel information:
switch# show san-port-channel summary
------------------------------------------------------------------------------
Interface
------------------------------------------------------------------------------
san-port-channel 7
san-port-channel 8
san-port-channel 9
The following example shows how to display SAN port channel consistency:
switch# show san-port-channel consistency
Database is consistent
The following example shows how to display details of the used and unused port channel numbers:
switch# show san-port-channel usage
Totally 3 port-channel numbers used
===================================
Used
Unused:
Autocreated SAN port channels are indicated explicitly to help differentiate them from the manually
created SAN port channels. The following example shows how to display an autocreated port channel:
switch# show interface fc2/1
fc2/1 is trunking
OL-16597-01
Total Ports
:
77 - 79
1 - 76 , 80 - 256
Hardware is Fibre Channel, FCOT is short wave laser
Port WWN is 20:0a:00:0b:5f:3b:fe:80
...
Receive data field Size is 2112
Beacon is turned off
Port-channel auto creation is enabled
Belongs to port-channel 123
Purpose
Displays SAN port channel information.
Displays information for the specified SAN port
channel.
Displays VSAN configuration information for the
specified Fibre Channel interface.
Oper Ports
2
0
2
0
2
2
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
Verifying SAN Port Channel Configuration
First Oper Port
--
--
36-15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents