About Port VSAN Membership

Port VSAN membership on the switch is assigned on a port-by-port basis. By default each port belongs
to the default VSAN. You can assign VSAN membership to ports using one of two methods:
VSAN trunking ports have an associated list of VSANs that are part of an allowed list (see
"Configuring VSAN

Assigning Static Port VSAN Membership

To statically assign VSAN membership for an interface port, perform this task:
Command
Step 1
switch# configuration terminal
Step 2
switch(config)# vsan database
switch(config-vsan-db)#
Step 3
switch(config-vsan-db)# vsan vsan-id
Step 4
switch(config-vsan-db)# vsan vsan-id interface
fc slot/port
or
switch(config-vsan-db)# vsan vsan-id interface
vfc slot/port
Step 5
switch(config-vsan-db)# vsan vsan-id interface
vfc slot/port
switch(config-vsan-db)# no vsan vsan-id
interface fc slot/port

Displaying VSAN Static Membership

To display the VSAN static membership information, use the show vsan membership command.
The following example displays membership information for the specified VSAN:
switch # show vsan 1 membership
vsan 1 interfaces:
Interface information is not displayed if interfaces are not configured on this VSAN.
Note
The following example displays membership information for all VSANs:
switch # show vsan membership
vsan 1 interfaces:
OL-16597-01
Statically—Assigning VSANs to ports.
See the
"Assigning Static Port VSAN Membership" section on page
Dynamically—Assigning VSANs based on the device WWN. This method is referred to as dynamic
port VSAN membership (DPVM). Cisco Nexus 5000 Series switches do not support DPVM.
Trunking").
fc2/1
fc2/2
fc2/3
san-port-channel 3
fc2/1
fc2/2
fc2/3
Purpose
Enters configuration mode.
Configures the database for a VSAN.
Creates a VSAN with the specified ID if that
VSAN does not exist already.
Assigns the membership of the specified
interface to the VSAN.
Updates the membership information of the
interface to reflect the changed VSAN.
Removes the interface from the VSAN.
fc2/4
vfc1/1
fc2/4
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
Configuring VSANs
37-7.
Chapter 35,
37-7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents