Viewing And Saving Diagnostic Information; Setting Up Automatic Trace Dump Transfers; Specifying A Remote Server; Enabling The Automatic Transfer Of Trace Dumps - HP A7533A - Brocade 4Gb SAN Switch Base User Manual

Hp storageworks fabric os 5.x procedures user guide (aa-rvhwb-te, september 2005)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

3.
Verify the IP address was deleted by issuing the syslogDipShow command.

Viewing and saving diagnostic information

Issue the supportShow command to dump important diagnostic and status information to the session
screen, where you can review it or capture its data.
To save a set of files that customer support technicians can use to further diagnose the switch condition,
issue the supportSave command. The command prompts for an FTP server, packages the following
files, and sends them to the specified server:
The output of the supportShow command
The contents of any trace dump files on the switch
System message logs (from both the CP blades for HP StorageWorks SAN Directors)
See also
"Setting up automatic trace dump

Setting up automatic trace dump transfers

You can set up a switch so that diagnostic information is transferred to a remote server. If a problem then
occurs, you can provide your customer support representative with the most detailed information possible.
To ensure the best service, set up for automatic transfer as part of standard switch configuration, before a
problem occurs.
Setting up for automatic transfer of diagnostic files involves the following tasks:
Specify a remote server on which to store the files.
Enable the automatic transfer of trace dumps to the server. (Trace dumps overwrite each other by
default; sending them to a server preserves information that would otherwise be lost.)
Set up a periodic checking of the remote server, so you are alerted if the server becomes unavailable
and you can correct the problem.
After the setup is complete, you can run the supportSave -c command to save diagnostic information
to the server (without specifying server details).
The following procedures describe in detail the tasks for setting up automatic transfer. For details on the
commands, see the HP StorageWorks Fabric OS 5.x command reference guide.

Specifying a remote server

1.
Verify that the FTP service is running on the remote server.
2.
Connect to the switch and log in as admin.
3.
Issue the following command:
supportftp -s
4.
Respond to the prompts as follows:
• For Host Name, enter the name or IP address of the server where the files are to be stored; for
example, 192.1.2.3.
• For user name, enter the user name of your account on the server; for example, JohnDoe.
• For password, enter your account password for the server.
• For remote directory, specify a path name for the remote directory. Absolute path names can
be specified using forward slash (/). Relative path names create the directory in the user's home
directory on UNIX servers, and they are created in the directory where the FTP server is running on
Windows servers.

Enabling the automatic transfer of trace dumps

1.
Connect to the switch and log in as admin.
2.
Issue the following command:
traceftp -e
140 Working with diagnostic features
transfers" on page 140.