7.
Enter the full path to the firmware file on the server.
For example:
/pub/v5.0.1/release.plist
8.
Enter your password.
9.
Answer the next prompts as indicated:
Do Auto Commit after reboot [Y]: y
If you answer no in the previous example, you must manually issue the firmwareCommit command.
Reboot system after download [N]: y
The default is no. If you take the default, you must later use the haReboot command to perform an
HA reboot manually.
NOTE:
After you upgrade to Fabric OS 4.4.0 or later, the Full Install option is no longer available.
For example:
switch: admin> firmwaredownload -s
Server Name or IP Address: 192.1.2.3
User Name: JohnDoe
File Name: /pub/v5.0.1/release.plist
Password: *****
Full Install (Otherwise upgrade only) [Y]: y
Do Auto Commit after reboot [Y]: y
Reboot system after download [N]: y
10.Wait for the firmware download to finish. (Start a new telnet session and use the
firmwareDownloadStatus command to check the status.)
11.Issue the haShow command to verify that the two CP blades are synchronized.
12.If you set the option to reboot to no, reboot the standby CP blade.
13.Log in to the same CP blade and issue the firmwareDownloadStatus command to verify that the
firmware has downloaded successfully and has either committed or is in the process of doing so. (If
you set the option to perform an autocommit after reboot to no in
firmwareCommit command manually.)
14.Issue the haFailover command to make the current CP blade active (with the updated firmware).
15.Repeat
step 1
through
step 13
on the other CP blade if the firmware versions are different.
step
9, you must issue the
Fabric OS 5.x administrator guide 241