Sample Resource Management Facility Configuration File For Mainframe - HP A7533A - Brocade 4Gb SAN Switch Base User Manual

Hp storageworks fabric os 5.x procedures user guide (aa-rvhwb-te, september 2005)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

IOCP (and not in decimal values); the Domain IDs in the following example are for demonstration
purposes only.
*------------------------------------------------------------------
* SilkWorm 24000 Domain_ID=61 (in hex)
*------------------------------------------------------------------
CNTLUNIT CUNUMBR=0D8,UNITADD=00,UNIT=2032,
PATH=(50,51),
IODEVICE ADDRESS=(0D8,1),CUNUMBR=0D8,UNIT=2032,STADET=Y,UNITADD=00
*---------------------------------------------------------------
*SilkWorm 12000 Domain_ID=22 (left side logical switch 0 in hex)
*---------------------------------------------------------------
CNTLUNIT CUNUMBR=0D9,UNITADD=00,UNIT=2032,
IODEVICE ADDRESS=(0D9,1),CUNUMBR=0D9,UNIT=2032,STADET=Y,UNITADD=00
*---------------------------------------------------------------
* SilkWorm 12000 Domain_ID=23 (right side logical switch 1 in hex)
*---------------------------------------------------------------
*
CNTLUNIT CUNUMBR=0DA,UNITADD=00,UNIT=2032,
IODEVICE ADDRESS=(0DA,1),CUNUMBR=0DA,UNIT=2032,STADET=Y,UNITADD=00
*------------------------------------------------------------------
* SilkWorm 3900 Domain_ID=25 (in hex)
*------------------------------------------------------------------
*
CNTLUNIT CUNUMBR=0DB,UNITADD=00,UNIT=2032,
IODEVICE ADDRESS=(0DB,1),CUNUMBR=0DB,UNIT=2032,STADET=Y,UNITADD=00
*
*------------------------------------------------------------------

Sample Resource Management Facility configuration file for mainframe

Resource management facility (RMF) is a performance management tool that measures selected areas of
system activity, including different views of the FICON channel. RMF presents data collected in the form of
System Management Facility (SMF) records. This data is essential for any kind of FICON channel
performance troubleshooting.
To obtain an RMF FICON director activity report, you must include the keyword FCD in the RMF
configuration file for the FICON director (this is generic for any FICON director). You must also define the
CUP port. In the following example, the keyword is boldfaced.
LINK=(61FE,61FE)
PATH=(8A,8B),
LINK=(22FE,22FE)
PATH=(92,93),
LINK=(23FE,23FE)
PATH=(5A,5B),
LINK=(25FE,25FE)
Fabric OS 5.x administrator guide 121

Advertisement

Table of Contents
loading

Table of Contents