switch:admin> switchstatusshow
Switch Health Report Report time: 03/21/2005 03:50:36 PM
Switch Name:
IP address:
SwitchState:
Duration:
Power supplies monitor
Temperatures monitor
Fans monitor
WWN monitor
Standby CP monitor
Blades monitor
Flash monitor
Marginal ports monitor
Faulty ports monitor
Missing SFPs monitor
All ports are healthy
switch:admin>
For more information on how the overall switch status is determined, see the switchStatusPolicySet
command in the HP StorageWorks Fabric OS 5.x command reference guide.

Displaying switch information

1.
Connect to the switch and log in as admin.
2.
Issue the switchShow command. This command displays the following information for a switch:
• switchname displays the switch name.
• switchtype displays the switch model and firmware version numbers.
• switchstate displays the switch state: Online, Offline, Testing, or Faulty.
• switchrole displays the switch role: Principal, Subordinate, or Disabled.
• switchdomain displays the switch Domain ID.
• switchid displays the embedded port D_ID of the switch.
• switchwwn displays the switch WWN.
• switchbeacon displays the switch beaconing state: either ON or OFF.
The switchShow command also displays the following information for ports on the specified switch:
• Module type: The SFP type, if an SFP is present.
• Port speed: The speed of the Port (1G, 2G, 4G, N1, N2, N4, or AN). The speed can be fixed,
negotiated, or auto-negotiated.
• Port state: The port status.
• Comment: Information about the port. This section might be blank or display the WWN for the
F_Port or E_Port, trunking state, upstream or downstream status.
The details displayed for each switch differ for different switch models. For more information, see the
switchShow command in the HP StorageWorks Fabric OS 5.x command reference guide.

Displaying the uptime for a switch

1.
Connect to the switch and log in as admin.
2.
Issue the uptime command.
SW3900
10.33.54.176
MARGINAL
863:23
MARGINAL
HEALTHY
HEALTHY
HEALTHY
HEALTHY
HEALTHY
HEALTHY
HEALTHY
HEALTHY
HEALTHY
Fabric OS 5.x administrator guide 131