Sample modification of the options for configuring SNMP MIB traps:
switch:admin>
The SNMP Mib/Trap Capability has been set to support
FE-MIB
SW-MIB
FA-MIB
FA-TRAP
FA-MIB (yes, y, no, n): [yes]
FICON-MIB (yes, y, no, n): [no]
HA-MIB (yes, y, no, n): [no]
SW-TRAP (yes, y, no, n): [no]
swFCPortScn (yes, y, no, n): [no]
swEventTrap (yes, y, no, n): [no]
swFabricWatchTrap (yes, y, no, n): [no]
swTrackChangesTrap (yes, y, no, n): [no]
FA-TRAP (yes, y, no, n): [yes]
connUnitStatusChange (yes, y, no, n): [no]
connUnitEventTrap (yes, y, no, n): [no]
connUnitSensorStatusChange (yes, y, no, n): [no]
connUnitPortStatusChange (yes, y, no, n): [no]
SW-EXTTRAP (yes, y, no, n): [no]
FICON-TRAP (yes, y, no, n): [no]
linkRNIDDeviceRegistration (yes, y, no, n): [no]
linkRNIDDeviceDeRegistration (yes, y, no, n): [no]
linkLIRRListenerAdded (yes, y, no, n): [no]
linkLIRRListenerRemoved (yes, y, no, n): [no]
linkRLIRFailureIncident (yes, y, no, n): [no]
HA-TRAP (yes, y, no, n): [no]
fruStatusChanged (yes, y, no, n): [no]
cpStatusChanged (yes, y, no, n): [no]
fruHistoryTrap (yes, y, no, n): [no]
Avoid-Duplicate-TRAP (yes, y, no, n): [no]
switch:admin>
The following snmpMibCapSet parameters for FA-TRAP appear in the preceding example:
connUnitStatusChange: Indicates that the overall status of the connectivity unit has changed. Its
variables are:
• connUnitStatus: The status of the connection unit
• connUnitState: The state of the connection unit
connUnitEventTrap: Indicates that the connectivity unit has generated an event. Its variables are:
• connUnitEventId: The internal event ID
• connUnitEventType: The type of this event
connUnitEventObject: Used with the connUnitEventType to identify the object to which the
event refers.
connUnitEventDescr: The description of the event.
connUnitSensorStatusChange: Indicates that the status of the sensor associated with the
connectivity unit has changed.
connUnitSensorStatus: The status indicated by the sensor.
connUnitPortStatusChange: Indicates that the status of the sensor associated with the
connectivity unit has changed.
connUnitPortStatus: Shows overall protocol status for the port.
connUnitPortState: Shows the user-specified state of the port hardware.
66
Configuring standard security features
snmpmibcapset
y
y
y
y
y
y
y