86

SULB-1035

Recommended
Reboot the switch. This will cause the internal image to be relocated again. Use the
Action
firmwareDownloadStatus to monitor the progress. If the problem persists, contact your switch
service provider.
Severity
ERROR
SULB-1035
Message
AUDIT, <timestamp>, [SULB-1035], ERROR, FIRMWARE, <event-initiator-details>,
<event-location>, , An error has occurred relocation of the internal image.
Probable Cause
Indicates that an error has occurred during the relocation of the internal image. The error may be
caused by inconsistent internal firmware image. It may also be caused by the internal Ethernet or
persistent storage hardware failure.
Recommended
Reset the switch. This will cause the internal image to be relocated again. If the problem persists,
Action
contact your switch service provider.
Severity
ERROR

SULB-1037

Message
AUDIT, <timestamp>, [SULB-1037], ERROR, FIRMWARE, <event-initiator-details>,
<event-location>, , HCL failed. Reboot the switch manually using the reboot
command. However, it will disrupt the FC traffic.
Probable Cause
Many reasons can cause HCL to fail, such as domain not confirmed.
Recommended
Run the reboot command to reboot the switch manually.
Action
Severity
Error
528