FW-1195

FW-1195
Message
<timestamp>, [FW-1195], <sequence-number>,, INFO, <system-name>, <Port Name>,
<Label>, is between high and low boundaries(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
Probable Cause
Indicates that the number of state changes that the port experiences has changed from a value
outside of the acceptable range to a value within the acceptable range. The state of the port has
changed for one of the following reasons: the port has gone offline, has come online, is testing, is
faulty, has become an E_Port, has become an F_Port, has segmented, or has become a trunk port.
Recommended
No action is required. Respond to this message as is appropriate to the particular policy of the
Action
end-user installation.
Severity
INFO

FW-1216

Message
<timestamp>, [FW-1216], <sequence-number>,, INFO, <system-name>, <Label>, value
has changed(High=<High value>, Low=<Low value>). Current value is <Value> <Unit>.
Probable Cause
Indicates that the number of arbitrated loop physical address (AL_PA) cyclic redundancy check
(CRC) errors has changed. This indicates that errors have been detected in the FC frame. Invalid
CRC messages occur when the number of CRC errors in Fibre Channel frames for specific source ID
(S_ID) and destination ID (D_ID) pairs change. These messages might also be caused by dirty
equipment, temperature fluctuations, and aging equipment.
Recommended
Verify that your optical components are clean and function properly. Replace deteriorating cables or
Action
small form-factor pluggables (SFPs). Check for damage from heat or age. You should set your high
boundaries to five- or six-digit figures, as only large numbers of messages indicate a problem in this
area.
Severity
INFO

FW-1217

Message
<timestamp>, [FW-1217], <sequence-number>,, INFO, <system-name>, <Label>, is
below low boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause
Indicates that the number of arbitrated loop physical address (AL_PA) cyclic redundancy check
(CRC) errors has fallen below the low boundary. This indicates that errors have been detected in the
FC frame. Invalid CRC messages occur when the number of CRC errors in Fibre Channel frames for
specific source ID (S_ID) and destination ID (D_ID) pairs change. These messages might also be
caused by dirty equipment, temperature fluctuations, and aging equipment. You should set your
high boundaries to five- or six-digit figures, as only large numbers of messages indicate a problem
in this area.
A low level of invalid CRC errors means that the switch is functioning normally.