Ts-1001; Ts-1002; Ts System Messages - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference Manual

Brocade error message reference guide v6.0.0 (53-1000600-01, april 2008)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

TS System Messages

TS-1001

Message
<timestamp>, [TS-1001], <sequence-number>,, WARNING, <system-name>, NTP Query
failed:
Probable Cause
Indicates that a network time protocol (NTP) query to the configured external clock server failed.
Local clock time on the principal or primary fabric configuration server (FCS) switch is used for
fabric synchronization.
This might be logged during temporary operational issues such as IP network connection issues to
the external clock server. If it does not recur, it can be ignored.
Recommended
Verify that the configured external clock server is available and functional. If that external clock
Action
server is not available, choose another.
Severity
WARNING

TS-1002

Message
<timestamp>, [TS-1002], <sequence-number>,, INFO, <system-name>, < Type of clock
server used > Clock Server used instead of < Type of clock server configured >:
locl: 0x<code> remote: 0x<code>
Probable Cause
Indicates that the fabric time synchronization distributed from the principal or primary fabric
configuration server (FCS) switch was not sourced from the Type of clock server configured,
instead, an alternate server was used, indicated by Type of clock server used. The type of clock
server used or configured might be either one of the following:
This might be logged during temporary operational issues such as IP network connection issues to
the external clock server or if the fabric is configured for external time synchronization but the
principal or primary FCS does not support the feature. If the message does not recur, it should be
ignored.
Recommended
Run the tsClockServer command to verify that the principal or primary FCS switch has the clock
Action
server IP configured correctly. Verify that this clock server is accessible to the switch and
functional. If the principal or primary FCS does not support the feature, either choose a different
switch for the role or reset the clock server to LOCL.
Severity
INFO
Fabric OS Message Reference
53-1000600-01
<error code>
LOCL
Local clock on the principal or primary FCS switch
External
External NTP server address configured
Chapter
75
463