Sulb-1033; Sulb-1034; Sulb-1035 - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference Manual

Brocade error message reference guide v6.0.0 (53-1000600-01, april 2008)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

Probable Cause
Indicates that the switch has rebooted with the new firmware and is relocating the AP firmware.
Recommended
Wait for the operation to complete.
Action
Severity
WARNING

SULB-1033

Message
<timestamp>, [SULB-1033], <sequence-number>, AUDIT, WARNING, <system-name>,
Switch has completed relocating the internal firmware image.
Probable Cause
Indicates that the firmwareDownload process has completed normally on the switch.
Recommended
Run the firmwareShow command to verify the firmware versions. Run the switchShow command to
Action
make sure the switch is enabled.
Severity
WARNING

SULB-1034

Message
<timestamp>, [SULB-1034], <sequence-number>, AUDIT, ERROR, <system-name>,
Firmwaredownload timed out.
Probable Cause
The error may be caused by a switch initialization issue after the internal image is relocated. It may
also be caused by an internal Ethernet issue or by persistent storage failure.
Recommended
Reboot the switch. This will cause the internal image to be relocated again. Use the
Action
firmwareDownloadStatus to monitor the progress. If the problem persists, contact your switch
service provider.
Severity
ERROR

SULB-1035

Message
<timestamp>, [SULB-1035], <sequence-number>, AUDIT, ERROR, <system-name>, An
error has occurred during relocation of the internal image.
Probable Cause
Indicates that an error has occurred during the relocation of the internal image. The error may be
caused by inconsistent internal firmware image. It may also be caused by the internal Ethernet or
persistent storage hardware failure.
Recommended
Reset the switch. This will cause the internal image to be relocated again. If the problem persists,
Action
contact your switch service provider.
Severity
ERROR
Fabric OS Message Reference
53-1000600-01
69
SULB-1033
445

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ae370a - brocade 4gb san switch 4/12

Table of Contents