12
EM-1062
Recommended
Please remove all blades of this type or upgrade your standby CP. Once an appropriate action is
Action
taken, this CP must be rebooted or haSyncStart must be run successfully. Until this is done, the
system will remain out of synchronization.
Severity
WARNING
EM-1062
Message
<timestamp>, [EM-1062], <sequence-number>,, CRITICAL, <system-name>, Blade in
slot <Slot Id> faulted as it exceeds the maximum support limit of <Limit> blades
with Blade ID <Blade Type Id> in the chassis.
Probable Cause
Too many blades of a particular type are in the system.
Recommended
Remove the faulted blade.
Action
Severity
CRITICAL
EM-1063
Message
<timestamp>, [EM-1063], <sequence-number>,, CRITICAL, <system-name>, Blade in
slot <Slot Id> faulted because it exceeds the maximum support limit of <Limit>
blades with Blade IDs <Applicable blade Type IDs> in the chassis.
Probable Cause
Too many blades of a set of particular types are in the system.
Recommended
Remove the faulted blade.
Action
Severity
CRITICAL
EM-1064
Message
<timestamp>, [EM-1064], <sequence-number>,, CRITICAL, <system-name>, Blade:<slot
ID> is being powered off (based on user configuration) upon receiving a HW ASIC
ERROR, reason:<Fault reason>.
Probable Cause
The blade is power off since a hardware (HW) application specific integrated circuit (ASIC) ERROR
was detected, and the user has selected to power off the problem blade when such a condition
occurred.
Recommended
Contact support.
Action
Severity
CRITICAL
92
Fabric OS Message Reference
53-1000600-01