CDR System Messages
CDR-1001
Message
<timestamp>, [CDR-1001], <sequence-number>,, ERROR, <system-name>, Port
number>
Probable Cause
Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, a faulty cable
between peer ports, or the port speed configuration does not match the capability of the SFP.
Recommended
Verify that you are using compatible SFPs on the peer ports.
Action
Verify that the SFPs have not deteriorated and that the Fibre Channel cable is not faulty. Replace
the SFPs or cable if necessary. If there is a speed configuration mismatch, replace the SFP with a
compatible one or change the configuration.
Severity
ERROR
CDR-1002
Message
<timestamp>, [CDR-1002], <sequence-number>, FFDC, ERROR, <system-name>, Port
<port number>
Probable Cause
Internal error.
Recommended
For a bladed system, issue the slotPowerOff and slotPowerOn commands on the blade to recover
Action
the system. For a non-bladed system, perform fastBoot on the switch to recover the system.
Severity
ERROR
CDR-1003
Message
<timestamp>, [CDR-1003], <sequence-number>, FFDC, CRITICAL, <system-name>, <slot
number>, <chip index> HW ASIC chip error type =0<chip error>
Probable Cause
Indicates an internal error in the application specific integrated circuit (ASIC) hardware that may
degrade data traffic.
Recommended
Whenever this error occurs, reboot the system at the next maintenance window. If the problem
Action
persists, replace the blade.