SEC-1074

Message
<timestamp>, [SEC-1074], <sequence-number>,, ERROR, <system-name>, Cannot execute
the command on this switch. Please check the secure mode and FCS status.
Probable Cause
Indicates that a security command was run on a switch that is not allowed to run it either because
it is in non-secure mode or because it does not have required fabric configurations server (FCS)
privilege.
Recommended
If a security operation that is not allowed in non-secure mode is attempted, do not perform the
Action
operation in non-secure mode. In secure mode, run the command from a switch that has required
privilege, that is, either a backup FCS or primary FCS.
Severity
ERROR

SEC-1075

Message
<timestamp>, [SEC-1075], <sequence-number>,, ERROR, <system-name>, Fail to
<operation>
Probable Cause
Indicates that there has been a corruption during the distribution of the security database. This can
only occur when the primary fabric configurations server (FCS) is distributing the security database
to the other switches in the fabric and local validation finds that there is an error in the security
database. This is a rare occurrence.
Recommended
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
Action
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity
ERROR

SEC-1076

Message
<timestamp>, [SEC-1076], <sequence-number>,, ERROR, <system-name>,
NoNodeWWNZoning option has been changed.
Probable Cause
Indicates that the NoNodeWWNZoning option has been changed. If the option is turned on, a zone
member can be added using node WWNs, but the member will not be able to communicate with
others nodes in the zone.
Recommended
Reenable the current zone configuration for the change to take effect.
Action
Severity
ERROR
Fabric OS Message Reference
53-1000600-01
new policy set on all switches.