3. Perform the appropriate following action based on the type of blade:
4. Perform the appropriate following action based on the type of blade:
5. Perform the appropriate following action based on the type of blade:
6. Verify that the power LED on the port blade is displaying a steady green light. If it does not turn
7.
8. Group and route the cables through the vertical cable fingers.
9. Replace the chassis door

RRP: Blade filler panel

This section describes how to remove and replace blade filler panels.

Removing a filler panel

ATTENTION
A filler panel should be removed only when being replaced with a port, application, or encryption
blade, or new filler panel. Any slot that is not occupied by a blade should be occupied by a filler panel
to ensure correct cooling of the chassis and protection from dust.
1. Remove the chassis door
2. Unscrew the thumb screw at the right of the panel using the Phillips screwdriver.
3. Pull the filler panel out of the chassis
PowerConnect B-DCX-4S Backbone Hardware Reference Manual
53-1001808-01
For FC8-16, FC8-32, FC8-48 port blades, FX8-24, FCOE10-24 application blades, and
FS8-18 encryption blade: Adjust the ejectors to the closed position by pulling them away
from the center of the blade.
For FC10-6 port blade, and FA4-18, and FR4-18i application blades: Close the ejectors by
pushing the handles toward the center of the blade until the ejectors lock. The levering
action of the handles seats the blade in the slot.
For FC8-16, FC8-32, FC8-48 port blades, FX8-24, FCOE10-24 application blades, and
FS8-18 encryption blade: Tighten the left and right thumb screws using the Phillips
screwdriver.
For FC10-6 port blade, and FA4-18, and FR4-18i application blades: Tighten the thumb
screw inside each handle using the Phillips screwdriver.
For FC8-16, FC8-32, FC8-48 port blades, FX8-24, FCOE10-24 application blades, and
FS8-18 encryption blade: Skip to step 6.
For FC10-6 port blade, and FA4-18, and FR4-18i application blades: Turn the blade on by
sliding the slider switch in the left ejector to the left, covering the thumb screw.
on, ensure that the blade is firmly seated.
Install the SFP or XFP (FC10-6 only) transceivers and cables in the port blade.
("RRP: Chassis
door").
("RRP: Chassis
door").
(Figure
22).

RRP: Blade filler panel

5