5

RRP: Core switch blade (CR4S-8)

ldconfig
glibc
bash
readline
terminfo
termcap
setup
<output truncated>
tz
mtracer-tool
lkcd
sysstat
Removing unneeded files, please wait ...
Finished removing unneeded files.
All packages have been downloaded successfully.
Firmwaredownload has completed successfully.
2008/07/03-15:05:56, [SULB-1002], 924,, INFO, Brocade DCX-4S, Firmwaredownload
command has completed successfully.
7.
8. Ensure that you are still logged in to the standby CP blade (the blade for which you just
9. Log back in to standby CP blade and type firmwaredDownloadStatus on the standby CP blade
10. Log out of the standby CP blade and log in to the active CP blade.
11. Type haEnable to re-enable HA on the active CP blade.
12. Type haShow and verify that the command output includes "HA Enabled Heartbeat Up". If not,
13. Type version or firmwareShow to verify that the firmware version has been updated.
14. Pack the faulty CP blade in the packaging provided with the new CP blade, and contact the
15. Replace the chassis door

RRP: Core switch blade (CR4S-8)

This section describes how to remove and replace a core switch blade. The PowerConnect
B-DCX-4S has two core switch blades: one in slot 3 and one in slot 6. Note that the blade shown in
the removal illustration
56
Type firmwareDownloadStatus to verify that the firmware has been updated.
changed the firmware level) and type reboot. The reboot of the standby CP will initiate a
firmwarecommit to the secondary partition and log you out.
to validate a successful commit. This may take 10 minutes.
NOTE
For FOS 6.3.0 and later, haEnable will cause the standby CP blade to reboot. Wait until the
power cycles and the POST completes before moving to the next step.
reenter the command until you have verified that redundancy is achieved.
PowerConnect B-DCX-4S supplier to determine the return procedure.
(Figure
##################################################
##################################################
##################################################
##################################################
##################################################
##################################################
##################################################
##################################################
##################################################
##################################################
##################################################
("RRP: Chassis
door").
24) is shown with EMI plugs installed.
PowerConnect B-DCX-4S Backbone Hardware Reference Manual