Logging in to the serial console port

Logging in to the serial console port

To log in to the PowerConnect B-DCX-4S through the serial connection, follow these steps.
1. When the terminal emulator application stops reporting information, press Enter. You receive
2. Log in to the PowerConnect B-DCX-4S as admin, using the default password: password. You are

Setting the IP addresses

The PowerConnect B-DCX-4S requires three IP addresses, which are configured using the
ipAddrSet command. IP addresses are required for both CP blades (CP0 and CP1) and for the
chassis management IP (shown as SWITCH under the ipAddrShow command) in the PowerConnect
B-DCX-4S.
NOTE
The default IP addresses and host names for the PowerConnect B-DCX-4S are:
– 10.77.77.75 / CP0 (the CP blade in slot 4 at the time of configuration)
– 10.77.77.74 / CP1 (the CP blade in slot 5 at the time of configuration)
ATTENTION
Resetting an IP address while the PowerConnect B-DCX-4S has active IP traffic or has management
and monitoring tools running, such as DCFM, Fabric Watch, and SNMP, can cause traffic to be
interrupted or stopped.
20
tip /dev/ttyb -9600
If ttyb is already in use, use ttya instead and enter the following string at the prompt:
tip /dev/ttya -9600
the following login prompt:
CP0 Console Login:
prompted to change the default passwords at initial login.
swDir login: admin
Password:
Please change your passwords now.
Use Control-C to exit or press 'Enter' key to proceed.
Password was not changed. Will prompt again at next login
until password is changed.
swDir:admin>
NOTE
Passwords can be 8 to 40 characters long. They must begin with an alphabetic character. They
can include numeric characters, the dot (.), and the underscore (_). Passwords are
case-sensitive, and they are not displayed when you enter them on the command line.
PowerConnect B-DCX4S Backbone Hardware Reference Manual
53-1001808-01