Message
123 TOO MANY
VOLUMES DETECTED
124 SPARES CLEARED
125 ACCESS CONTROL
CONFLICT DETECTED
126 ACCESS CONTROL
RESOURCES EXCEEDED
150 BEACON ON
52
LCD panel and message descriptions
Type
Description
Error
The array controller only
supports a maximum of
32 configured volumes.
More volumes than that
were detected at power up.
This typically occurs when
migrating a set of volumes
from one array controller to
a different array controller
that already has configured
volumes on it. The migrated
volumes have not been
added.
Informational
A set of volumes has been
migrated from one array
controller to a different
array controller that already
has configured volumes on
it. The migrated volumes
have spares defined for
them that conflict with the
existing configuration. The
defined spares have been
deleted so as to allow the
migration to proceed.
Error
A set of volumes has been
migrated from one array
controller to a different
array controller that already
has configured volumes on
it. The migrated volumes
have access controls
defined for them that
conflict with the existing
configuration. The access
controls have been modified
so as to allow the migration
to proceed.
Error
A set of volumes has been
migrated from one array
controller to a different
array controllers that
already has configured
volumes on it. The migrated
volumes have access
controls defined for them
that conflict with the existing
configuration. The access
controls have been modified
so as to allow the migration
to proceed.
Informational
The LEDs on the MSA
and all connected hard
drives are blinking because
that array controller was
selected for identification
or configuration in a
host-based application such
as the ACU.
Action
Remove the migrated
volumes and run the Array
Configuration Utility (ACU).
Delete any unneeded
volumes until the number
of existing volumes plus the
number of migrated volumes
is 32 or less. Add the
migrated volumes back.
Run the Array Configuration
Utility (ACU) or MSA
Command Line Interface
(MSA-CLI) to reassign spare
hard drives as needed.
Run the Array Configuration
Utility (ACU) or MSA
Command Line Interface
(MSA-CLI) to check the new
access controls and modify
them if needed.
Run the Array Configuration
Utility (ACU) or MSA
Command Line Interface
(MSA-CLI) to check the new
access controls and modify
them if needed.