Message
412 STORAGE BOX
#<n> EMU NOT
RESPONDING
413 STORAGE BOX
#<n> EMU VERSION
<version>
414 STORAGE BOX
#<n> HOT REMOVED
415 STORAGE BOX
#<n> HOT ADDED
450 INVALID SCSI
CABLING BOX #<n>
500 INITIALIZING
PCI SUBSYSTEM
501 PCI SUBSYSTEM
HARDWARE FAILURE
502 PCI BRIDGE ASIC
SELF TEST FAILURE
510 INITIALIZING
FIBRE CHANNEL
SUBSYSTEM
Type
Description
Error
An EMU in the specified
storage enclosure is not
responding to commands.
Informational
The version of firmware
running on the EMU. This
is only displayed for the
internal EMU of the MSA
chassis. It is not displayed
for externally connected
storage boxes.
Informational
An external storage
enclosure has been
hot-removed from the
back of the MSA.
Informational
An external storage
enclosure has been
hot-added to the back
of the MSA.
Error
The MSA has detected an
external storage enclosure
that is cabled incorrectly.
Informational
The array controller's
PCI subsystem is being
initialized as part of the
power-up sequence.
Error
The array controller's PCI
subsystem has encountered
a critical error during the
power-up sequence.
Error
The array controller's
PCI bridge ASIC has
encountered a critical
error during the power-up
sequence.
Informational
The array controller's Fibre
Channel subsystem is being
initialized as part of the
power-up sequence.
Action
Make sure the storage box
is powered on. Ensure
all cables are connected
securely. Power off the MSA
and the storage enclosure.
Then reapply power to the
storage box and then the
MSA.
Should the issue persist,
contact HP support.
Verify that the external
storage enclosures are
connected properly to the
MSA. For more information,
see the MSA installation
guide.
Remove the failed array
controller, wait 10 seconds,
and then reinsert the array
controller, ensuring that it is
fully seated in the chassis.
Should the issue persist,
contact HP support.
Remove the failed array
controller, wait 10 seconds,
and then reinsert the array
controller, ensuring that it is
fully seated in the chassis.
Should the issue persist,
contact HP support.
maintenance and service guide