Message
04 ENABLE VOLUMES ?
'<'=NO, '>'=YES
05 SYSTEM NAME
<name>
06 RESTARTING
SYSTEM
07 CLONE FIRMWARE?
'<'=NO, '>'=YES
08 CONTROLLER TOO
OLD NOT SUPPORTED
09 PILOT 2 CONTRLR
NOT SUPPORTED
38
LCD panel and message descriptions
Type
Description
User input
An issue has been found
with all of the configured
volumes that may result in
data loss. The exact nature
of the issue is detailed in a
previous display message.
Informational
The user assigned name for
the MSA system. This name
can be assigned using
the Array Configuration
Utility (ACU) or the MSA
Command Line Interface
(MSA-CLI).
Informational
The system is being
restarted.
User input
In dual-controller
configurations only,
the array controller has
detected a firmware version
mismatch with the two
controllers and wants to
copy the firmware from the
other controller onto this
controller. Firmware on
both controllers must match.
Error
During startup, the firmware
examines the hardware to
ensure that it is supported
for use with the version of
installed firmware.
This controller is not
supported.
Error
During startup, the firmware
examines the hardware to
ensure that it is supported
for use with the version of
installed firmware.
This controller is not
supported.
Action
Yes = the volume is enabled
(regardless of the issue.) The
volume attempts to return to
its normal operating state
and the data is accessible.
No = not selecting any
option within the time-out
period = the volume remains
disabled. The volume stays
in the failed state and the
data is not be accessible.
During this time, the user can
attempt to fix the issue.
no input = No
Scroll through and read the
messages on both controller
LCD panels to confirm the
currently installed firmware
versions on the controller.
Then, respond appropriately
to the prompt.
< = No, do not clone.
> = Yes, proceed with the
cloning.
no input = Yes, proceed with
the clone.
During a restart of the MSA
chassis, the controller with
the latest version of firmware
is cloned.
If a new or replacement
controller is hot-added,
the firmware on the already
installed and active controller
is cloned, even if less recent.
Contact HP support.