Installing The Component; Verifying Proper Operation; Replacing A Scsi I/O Module; Before You Begin - HP AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive Maintenance And Service Manual

Modular smart array
Hide thumbs Also See for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive:
Table of Contents

Advertisement

Installing the component

Slide the replacement fan module into the MSA chassis bay until the module clicks into place.

Verifying proper operation

After replacing the fan module, verify that:
The fan starts operating immediately.
The fan Status LED is On.
No new error messages are displayed on the array controller LCD panel.

Replacing a SCSI I/O module

Before you begin

CAUTION:
Before removing a component or blanking panel from an operational device, make sure that you
have the replacement part available. Removing a component or blank impacts the airflow and
cooling ability of the device. To avoid possible overheating, insert the new or replacement component
within one or two minutes. If the internal temperature exceeds acceptable limits, the device may
overheat and automatically shut down or restart.
Parts can be damaged by electrostatic discharge. Use proper anti-static protection.
2
1
15521
15522