Installing The Component; Verifying Proper Operation; Replacing The Msa1500 Chassis - HP AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive Maintenance And Service Manual

Modular smart array
Hide thumbs Also See for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive:
Table of Contents

Advertisement

3.
While pressing the power supply module latch (1) to the left, grasp the module handle and pull the
defective power supply out of the chassis (2).

Installing the component

1.
Slide the replacement power supply module into the MSA chassis bay until the module clicks into
place.
2.
Connect the AC power cord to the power supply.

Verifying proper operation

After replacing the power supply, verify that:
The power supply Status LED is solid green.
No new error messages are displayed on the array controller LCD panel.

Replacing the MSA1500 chassis

In the event of a backplane board failure, a new chassis must be ordered. All original component parts
of the MSA can be reinstalled in their respective locations on the new backplane. The parts that will be
removed from the old chassis and then reinstalled in the new chassis include:
Controllers or blank
Hard drives or blanks
Power button module
Fibre Channel I/O modules or interconnect blank
Fan modules
SCSI I/O modules or blanks
Power supply modules
When finished, write the serial number of the original chassis on the label of the replacement chassis.
92
Customer replaceable components
1
2
15494
15495

Advertisement