Message
52 REDUNDANCY
FAILED PCI BUS
ERROR
53 REDUNDANCY
FAILED NO SECOND
CONTROLLER
54 REDUNDANCY
FAILED CACHE DIMMS
MISMATCH
55 MSA1000 ACTIVE
CONTROLLER
56 MSA1000 STANDBY
CONTROLLER
57 REMOVE OTHER
CONTROLLER NOW
44
LCD panel and message descriptions
Type
Description
Error
While either attempting
to enter redundant mode
or already operating in
redundant mode, one
of the array controllers
encountered a PCI bus
error on the communication
channel used between
the two array controllers.
Redundancy is disabled at
this time.
Error
While operating in
redundant mode, one
of the array controllers was
removed. Redundancy is
disabled at this time.
Error
The cache memory modules
on the two controllers are
not the same size. All
cache memory modules
must be the same size for
redundancy to operate.
Informational
In dual-controller
active/passive
configurations, this
message is displayed
on the active controller and
56 MSA1000 STANDBY
CONTROLLER is displayed
on the standby controller.
In dual-controller active/
active configurations, this
message is displayed on
both controllers.
Informational
In dual-controller
active/passive
configurations, this
message is displayed on
the standby controller and
55 MSA1000 ACTIVE
CONTROLLER is displayed
on the active controller.
Error
In dual-controller
configurations, the firmware
has determined that the
other controller has been
disabled and can safely be
removed.
Action
If the MSA is currently
involved in host I/O, remove
the standby array controller,
wait 10 seconds, and then
reinsert it, ensuring that it is
fully seated in the chassis.
If this does not resolve the
issue, wait until downtime
is available. Power off the
MSA, remove both array
controllers, and reinsert
them, ensuring they are fully
seated in the chassis.
Should the issue persist,
contact HP support.
Reinsert the missing array
controller ensuring that it is
fully seated in the chassis.
Remove the array controller
that has been halted, replace
the cache modules with the
appropriately sized ones,
wait 10 seconds, and then
reinsert the array controller,
ensuring that it is fully seated
in the chassis.
Remove the other array
controller for the planned
service. When complete,
reinsert the array controller,
ensuring that it is fully seated
in the chassis.
Need help?
Do you have a question about the AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive and is the answer not in the manual?