Removing Power From The Msa - HP AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive Maintenance And Service Manual

Modular smart array
Hide thumbs Also See for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive:
Table of Contents

Advertisement

Removing power from the MSA

CAUTION:
System power to the MSA does not shut off completely with the power switch. The two positions of the
front panel power switch should be considered as
standby position removes power from most of the electronics and the hard drives, but portions of the
power supply and some internal circuitry remain active.
To remove all power from the system, you must disconnect the power cord from the storage system.
In systems with multiple power supplies, you must disconnect all the power cords to remove power
completely from the system.
To remove power from the MSA, do the following:
1.
Ensure that a known good backup is available.
2.
Schedule a maintenance window.
3.
From the servers in the network, stop all access to the MSA.
4.
Press and hold down the MSA Power On/Standby button for five seconds to place the MSA in
Standby mode.
NOTE:
Placing the MSA in standby mode disables the main power supply output, but still provides
auxiliary power (+5V) to the device.
5.
Verify that the Power On/Standby button LED is amber/off and that the fans are off.
6.
Disconnect all power cords from the AC outlets, and then from the device.
7.
Disconnect all external peripheral devices from the MSA.
72
Customer replaceable components
On
Standby
and
, rather than
On
Off
and
. The

Advertisement

Table of Contents
loading