Installing An Additional Microprocessor - IBM x3655 - System - 7985 Installation Manual

Installation guide
Hide thumbs Also See for x3655 - System - 7985:
Table of Contents

Advertisement

Complete the following steps to install a drive in a hot-swap bay.
Attention:
than 10 minutes without either a drive or a filler panel installed in each bay.
1. Read the safety information that begin on page v, and "Installation guidelines"
2. Remove the filler panel from one of the empty hot-swap bays.
3. Install the hard disk drive in the hot-swap bay:

Installing an additional microprocessor

The following notes describe the type of microprocessor that the server supports
and other information that you must consider when installing a microprocessor:
v The server supports up to two AMD Opteron microprocessors. If the server
v You might have to update the BIOS code. Be sure to read the documentation
v (Optional) Obtain an SMP-capable operating system. For a list of supported
v To order an additional microprocessor, contact your IBM marketing representative
v The microprocessor speeds are automatically set for this server; therefore, you
v If you have to replace a microprocessor, call for service.
v If the thermal-grease protective cover (for example, a plastic cap or tape liner) is
v Do not remove the first microprocessor from the system board to install the
To maintain proper system cooling, do not operate the server for more
on page 9.
a. Make sure that the tray handle is open (that is, perpendicular to the drive).
b. Align the drive assembly with the guide rails in the bay.
c. Gently push the drive assembly into the bay until the drive stops.
d. Push the tray handle to the closed (locked) position.
e. Check the hard disk drive status LED to verify that the hard disk drive is
operating properly.
If the amber hard disk drive status LED for a drive is lit continuously, that
drive is faulty and must be replaced. If the green hard disk drive activity LED
is flashing, the drive is being accessed.
Note: You might have to reconfigure the disk arrays after installing hard disk
drives. See the RAID documentation on the IBM ServeRAID Support CD for
more information.
If you have other devices to install, do so now. Otherwise, go to"Completing the
installation" on page 29.
comes with one microprocessor, you can install a second microprocessor but it
must be the same type and speed.
that comes with the microprocessor so that you can determine whether you have
to update the BIOS code. You can download the latest level of BIOS code and
many other code updates for your server at http://www.ibm.com/servers/eserver/
support/xseries/index.html.
operating systems and other optional devices, go to http://www.ibm.com/servers/
esever/serverproven/compat/us/.
or authorized reseller.
do not have to set any microprocessor frequency-selection jumpers or switches.
removed from the heat sink, do not touch the thermal grease on the bottom of
the heat sink or set down the heat sink.
second microprocessor.
Chapter 2. Installing optional devices
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3655 type 7985System x3655

Table of Contents