IBM QS22 - BladeCenter - 0793 Service Manual page 91

Problem determination and service guide
Hide thumbs Also See for QS22 - BladeCenter - 0793:
Table of Contents

Advertisement

Table 8. BMC test results
Test
Number
Status
166-801-
Abort
xxx BMC
166-802-
Abort
xxx BMC
166-803-
Abort
xxx BMC
166-804-
Abort
xxx BMC
166-805-
Abort
xxx BMC
166-806-
Abort
xxx BMC
166-807-
Abort
xxx BMC
166-808-
Abort
xxx BMC
166-809-
Abort
xxx BMC
166-810-
Abort
xxx BMC
166-811-
Abort
xxx BMC
166-812-
Abort
xxx BMC
Extended
results
Actions
BMC I2C test
1. Turn off the system and disconnect it from power. The
canceled: the
system must be removed from AC power in order to reset
BMC returned
the BMC.
an incorrect
2. After 45 seconds, reconnect the system to power and turn
response length.
on the system.
BMC I2C test
3. Run the test again.
canceled: the
4. Make sure that the DSA Diagnostic code is at the latest
test cannot be
level. The latest level DSA Diagnostic code can be found
completed for an
on the IBM Support Web site at http://www.ibm.com/
unknown reason.
support/docview.wss?uid=psg1SERV-DSA/.
BMC I2C test
5. Check BMC firmware level and upgrade if necessary. The
canceled: the
installed firmware level can be found in the DSA Diagnostic
node is busy; try
Event Log within the Firmware/VPD section for this
later.
component. The latest level firmware for this component
BMC I2C test
can be found on the IBM Support Web site at
canceled: invalid
http://www.ibm.com/support/us/en/.
command.
6. Run the test again.
BMC I2C test
7. If the test continues to fail, refer to the other sections of this
canceled: invalid
chapter for diagnosis and corrective action.
command for the
given LUN.
BMC I2C test
canceled:
timeout while
processing the
command.
BMC I2C test
canceled: out of
space
BMC I2C test
canceled:
reservation
canceled or
invalid
reservation ID
BMC I2C test
canceled:
request data
was truncated.
BMC I2C test
canceled:
request data
length is invalid.
BMC I2C test
canceled:
request data
field length limit
is exceeded.
BMC I2C test
canceled: a
parameter is out
of range.
Chapter 5. Diagnostics and troubleshooting
73

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bladecenter qs22 type 0793

Table of Contents