Table 13. System firmware boot errors (continued)
Code
Message
E5030
(USB) Device communication error Firmware cannot communicate
E5040
(USB) Device transaction error.
<command>
Note: <command> indicates the
command in progress when the
transaction error occurred. This
information may not always be
available.

Network boot errors

The following table describes the network boot errors.
84
BladeCenter QS22 Type 0793: Problem Determination and Service Guide
Description
with the BladeCenter USB
devices.
The drive showed an error during
data transfer.
Action
This could be a firmware or
physical hardware problem.
Check:
The Advanced Management
v
Module for messages
v The system firmware image is
not corrupt. See "System
firmware update errors" on page
79 for more information about
possible errors and their
solution.
v Other blade servers within the
BladeCenter unit to see if they
have the problem. If they do,
the BladeCenter unit itself may
be the cause of the problem.
See the Problem Determination
and Service Guide for your
BladeCenter unit for more
information.
Finally, power down then reboot
the blade. If this does not help
resolve the problem, contact your
IBM service representative.
1. Verify that the media tray is
assigned to the blade server.
Note: A reboot of the blade
server the to which the media
tray was previously assigned is
required.
2. Check that the correct media is
inserted and that the drawer is
closed.
3. Inspect the media to see if
there is visible damage.
4. Use another CD or DVD drive
to check that the media is
readable.
5. Check with other blade servers
within the BladeCenter unit to
see if they have the problem. If
they do, the BladeCenter unit
itself may be the cause of the
problem. See the Problem
Determination and Service
Guide for your BladeCenter
unit for more information.