Table 21. BMC firmware messages (continued)
Message
Severity
Blade x throttled.
Information Acoustic mode
where
x is the number of
the blade server in
the BladeCenter
unit.
Processor 1 (CPU 1
Warning
Chip) over warning
threshold.
Reading: x,
Threshold: 88.00.
where
x is the temperature
of the processor.
Processor 2 (CPU 2
Warning
Chip) over warning
threshold.
Reading: x,
Threshold: 88.00.
where
x is the temperature
of the processor.
Event
IBM PowerXCell 8i processor 1
Temp above Warning
Temperature (>78 °C)
Standard mode
IBM PowerXCell 8i processor 1
Temp above Warning
Temperature (>90 °C)
Standard mode
IBM PowerXCell 8i processor 1
Temp above Warning
Temperature (>88 °C)
Standard mode
IBM PowerXCell 8i processor 2
Temp above Warning
Temperature (>88 °C)
Automatic Action by
BMC
Throttle (Reduce
Frequency).
This is a BladeCenter unit
operation which reduces
processor speed on the
blade server concerned
until the temperature has
dropped to normal levels.
Advanced Management
Module increases blower
speed.
Advanced Management
Module increases blower
speed.
Chapter 5. Diagnostics and troubleshooting
Action required by
user
No action required.