Table 21. BMC firmware messages (continued)
Message
Severity
Blade memory fault.
Error
Memory device x+1
(DIMM x+1 Err)
uncorrectable ECC
memory error.
Memory device x
(DIMM x Err)
uncorrectable ECC
memory error.
Processor y (CPU y
Status) internal
error.
Memory bank y,
Error
memory (DIMM x or
x+1 PFA) predictive
failure
Memory device y,
Error
memory (IOBUF x
PFA) predictive
failure
Front panel critical
Error
Interrupt
Firmware BIOS
Warning
ROM Corruption
detected
PCI-X card not
Error
supported
106
BladeCenter QS22 Type 0793: Problem Determination and Service Guide
Event
Checkstop due to memory
fault.
Predictive failure on memory
channel y for main memory of
IBM PowerXCell 8i.
Predictive failure on buffer
memory IOBUFx of the IBM
PowerXCell 8i companion chip.
Other events
NMI reset button on Front
panel pressed
Boot WDT Timeout (Firmware
Corrupted)
DIAGS: Invalid PCI-X Card
Recovery messages
Automatic Action by
BMC
Soft-Reset
Reboot & Switch to the
permanent flash side
None
Action required by
user
Replace the affected
pair of DIMMs x and
x+1
Replace the affected
pair of DIMMs x and
x+1
Replace DIMM
IOBUFx
None. This is a
user-initiated action.
Reinstall TEMP
image. See
"Recovering the
system firmware
code" on page 64 for
further information.
No power on, PCI-X
expansion card needs
to be replaced

Advertisement