Status And Error Pages - Kyocera Ai5555 Instruction Handbook Manual

Network interface card
Hide thumbs Also See for Ai5555:
Table of Contents

Advertisement

Troubleshooting

Status and Error Pages

Status Page
Below is the status page that is printed when NC-2 is first powered on and
after it passes its self-tests. See Definition of Terms below.
Unit Serial Number: 841001
--------------------------------------------------------------------------------------------------------
Network Address: 00:40:af:66:a9:48
Network Topology: Ethernet
Network Speed: 10 Mega Bits
Novell Network Information
Novell Print Server Name: OLD
Directory Services Context not defined
Frame Type: Novell 802.3
AppleTalk Network Information
Frame Type: 802.2 SNAP ON 802.3
Protocol Address: NET Number 10
Preferred AppleTalk Zone: Default Zone
TCP/IP Network Information
Frame Type: Ethernet II
---------------------------------------------------------------------------------------------------------
Port Number: 1
Novell Connection Information
Printer Name: QA2_0
File Server: QA2
Definition of Terms
1. Unit Serial Number: The serial number listed on the NC-2 card.
2. Version: Version number of the firmware.
3. Network Address: Physical address of NC-2 used to install/configure
the NC-2 in TCP/IP environment and identify the unit Ethernet traces.
4. Network Topology: Ethernet.
5. Connector: Type of Ethernet connection you are using.
6. Novell Network Information: Print server name and the frame type.
7. AppleTalk Network Information: NC-2 frame type and node number.
8. TCP/IP Network Information: Frame Type; subnet mask default is 255.0.0.0; protocol
address (default is not configured, IP is not assigned).
Use the status page to check if the protocols you are using are defined. If a protocol is not
defined, first make sure the protocol is enabled. Protocols are enabled and disabled in the
Network Management Utility. (Refer to Section 3 NetWare Configuration)
6-4
Troubleshooting
Port Type: Parallel
Queue: QA2
Notify:
Version: 1.05
Connector: 10 Base T
enabled
Password Defined: Yes
enabled
Node Number
Socket Number
202
enabled
Protocol Address: 199.92.187.128
Priority: 1
Attached: Yes
First:
60
Repeat:
128
60