ReadChannel stands for the channel number used in this setup. A second port
number can be derived from this by adding one to ReadChannel. Portnumber
is used to specify the relative port.
• Interface iucv:
IUCVPeer=PARTNER
Enter the name of the peer machine.
• Network device type osa with interface qdio for OSA-Express Gigabit Ethernet
and OSA-Express High-speed Token Ring:
ReadChannel=0.0.0524
WriteChannel=0.0.0525
DataChannel=0.0.0526
Portname=FEF400
For ReadChannel, enter the number of the READ channel. For WriteChannel,
enter the number of the WRITE channel. DataChannel specifies the DATA
channel. For Portname, enter an appropriate port name. Make sure that the READ
channel carries an even device number.
• Interface hsi for HiperSockets and VM guest LANs:
ReadChannel=0.0.0624
WriteChannel=0.0.0625
DataChannel=0.0.0626
For ReadChannel, enter the appropriate number for the READ channel. For
WriteChannel and DataChannel, enter the WRITE and DATA channel
numbers.
4.4.3 Specifying the Installation Source and
YaST Interface
Install=nfs://server/directory/DVD1/
Specify the location of the installation source to use. Possible protocols are nfs,
smb (Samba/CIFS), ftp, and http.