HP 12000 User Manual page 144

Hp 12200 gateway virtual library system user guide (bw403-10001, june 2011)
Hide thumbs Also See for 12000:
Table of Contents

Advertisement

Table 19 CLI Monitoring Commands
Command
getHealth
getChassis
getNode
getNodeNames
getNodeFault
getNotificationsCount
getNotificationsDate
deleteNotifications
addEmailServer
getEmailServer
deleteEmailServer
addEmail
144 CLI Command Set
1
Usage
Returns the VLS health status as a number (0-good, 1-degraded, 2-critical, 3-failed,
4-missing).
Returns information about the VLS displayed on the Identity Tab window.
Returns information on the node. Where the options are:
-a <s> - Node name (Head_0, ...) (required)
-h - Displays command usage information (optional)
Returns the list of nodes in the VLS.
Returns fault information for the specified node. Where the options are:
-a <s> - Node name (Head_0, ...) (required)
-h - Displays command usage information (optional)
Returns the number of notification messages specified counting back from the most recent.
Where the options are:
-n <n> - Maximum number of notifications to return (required)
-h - Displays command usage information (optional)
Returns all the notification alert messages that occurred starting with the specified date.
Where the options are:
-d - mm/dd/yy on or after this date (required)
-h - Displays command usage information (optional)
Deletes the specified notification alerts from the VLS. Where the options are:
-id <s> - ID number of notification to delete (required)
-h - Displays command usage information (optional)
Specifies an E-mail server with an SMTP gateway to route notification alerts from the
VLS. Where the options are:
-a <s> - E-mail server address (required)
-c <s> - node IP address (required)
-s <s> - Sender email address (optional)
-h - Displays command usage information (optional)
Returns the E-mail server configuration settings for notification alerts.
Deletes the specified E-mail server from the E-mail notification alerts settings. Where the
options are:
-a <s> - E-mail server address (required)
-c <s> - VLS node IP address (required)
-f - Force - This parameter is ignored and is present only for backward compatibility
(optional)
-h - Displays command usage information (optional)
Adds an E-mail address and desired report formatting to the E-mail notification alert
settings. Where the options are:
-a <s> - E-mail address (required)
-c <s> - VLS IP address (required)
-s <n> - Severity (1-Error, 2-Warning, 4-Info, or 8-Unknown) (optional)
-y <n> - E-mail type (1-Long with attachment, 2-Long, 4-Short, or 8-Reports) (optional)
-h - Displays command usage information (optional)
-f <n> - Notification frequency (0-None, 1-Daily, 2-Weekly, 3-Bi-weekly, or 4-Monthly)
(optional)

Advertisement

Table of Contents
loading

This manual is also suitable for:

12200