Private Lan Dual Pathing; Managing Cartridges; Accessing The Cartridge Parameters Window - HP 12000 User Manual

Hp 12200 gateway virtual library system user guide (bw403-10001, june 2011)
Hide thumbs Also See for 12000:
Table of Contents

Advertisement

4.
Select Fix Primary Paths from the task bar to display the Fix Primary Paths Wizard.
5.
Select Apply to set all paths back to their original settings.
CAUTION:
array might reassign paths or fail-over preferences. This will limit device performance because all
data traffic will be routed through a single controller. To restore performance, from Command
View EVA:
1.
Reset path fail-over preferences for each LUN to no preference.
2.
Save the presentation.
3.
Reset the path fail-over preferences back to their original values.
4.
Save the presentation.
5.
Reboot the VLS system.

Private LAN Dual Pathing

The private LAN on the VLS has dual pathing which consists of a cable from each switch to each
node. If a LAN switch or a path to a LAN switch fails, the data transfer will automatically fail-over
to the other available switch.
The primary path is through NIC 2 of the switch and is referred to in the error notification as
eth1. If the LAN switch associated with NIC2 fails, the Notifications tab will display all eth1
failures.
The secondary path is through the USB LAN cable and is identified as eth2 in the error
notification. If the LAN switch associated with the USB LAN cable fails, the Notifications tab
will display all eth2 failures.
If both paths fail, the critical alert will identify bond 0 as the combined failed path. If both
paths from the private LAN to a secondary node fails, the node is off-line; but if both paths to
a primary node fails, the whole device is off-line.
When a failure occurs, repair the failure. In most cases, the system will automatically recognize
that the repair is complete and restore the path or paths without having to reboot the system;
however, you may need to reboot the system if the repair includes installing a new USB LAN
adapter.

Managing Cartridges

You can change the following parameters for existing cartridges from the Cartridge Parameters
window:
Library with which they are associated
Capacity
Write access

Accessing the Cartridge Parameters Window

To access the Cartridge Paramenters window, from Command View VLS:
1.
Click the System tab.
2.
Select Cartridges in the navigation tree.
The Cartridge Details window opens.
3.
Select the number of cartridges to display from the Cartridges per Page list beside the group
of cartridges you wish to edit. Options are 10, 50, 100 (default), 500, or 1024 cartridges.
If you attempt to reboot during a path failure without first repairing the failure, the
Managing Cartridges 105