SNMP Notification

To receive VLS notification alerts on a management consoles, you must edit the SNMP settings to
specify the management consoles you want to receive VLS SNMP traps.

Editing the SNMP Settings

NOTE:
To display VLS notification alerts on a management console, the management console
must be running HP Systems Insight Manager, and be configured to receive SNMP traps from the
VLS.
To add a management consoles to the SNMP alert distribution list from Command View VLS:
1.
Click the Notifications tab.
The Notifications window displays.
2.
Click Edit SNMP Setting in the task bar.
The Edit SNMP Settings window opens
Figure 28 Edit SNMP Settings window
3.
To add management consoles:
a.
Enter the host name of a management console that you want to receive VLS SNMP traps
in the Hostname box.
b.
Enter the string name that is passed with the set to get commands from the management
console in the Community String box.
This value is typically set to Public.
c.
Select the appropriate trap version for the management application that will receive the
SNMP traps in the Trap Version box.
Select 1 for the trap version if your management application is HP Systems Insight
Manager.
d.
Click Add.
e.
To add another management console, repeat these steps.
You can add up to 8 management consoles.
1 16
Monitoring
(Figure 28 (page
116)).