2 Hardware Installation

This section details the steps to install the VLS hardware from installation preparation to final cabling.

Preparing for the Installation

Prepare the EVA for the VLS12000 Gateway

Arrays that will be connected to the VLS Gateway must already be setup with the appropriate
configuration as described in the solutions guide, including:
Command View EVA is installed, at firmware revision 5100 or later, and functioning properly.
There are either two external Fibre Channel switches/fabrics or two zones on an external
Fibre Channel switch/fabric so that there are two (high availability) data pathways from the
VLS Gateway to the EVA.
All of the VRaid LUNs required for the VLS have been created on the EVA according to the
design guidelines (for example, each LUN is roughly the same size—2 TB is preferred. The
LUNs can not be read-only. RAID 5 is recommended. Path failover is balanced across both
EVA controllers).
NOTE:
Gateway meet this requirement.
If this has not been done, refer to the solutions guide for instructions.

Tools for Installation

Two people
#1 and #2 Phillips screwdriver
Box cutting knife
CAUTION:

Taking ESD Precautions

To prevent damaging the system, be aware of the precautions you need to follow when setting up
the system or handling parts. A discharge of static electricity from a finger or other conductor may
damage system boards or other static-sensitive devices. This type of damage may reduce the life
expectancy of the device.
To prevent electrostatic damage:
Avoid hand contact by transporting and storing products in static-safe containers.
Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations.
Place parts on a grounded surface before removing them from their containers.
Avoid touching pins, leads, or circuitry.
Always be properly grounded when touching a static-sensitive component or assembly.