Actions Required When Recording Errors Occur

When a recording error occurs (e.g., data is missing) during playback, you can troubleshoot the cause by checking the
information in the event log and the Storage Server log file.
Event
Error: Cannot Connect to Camera
Recording Frame Rate reduced
due to high load issues
Recording Suspended
(Low Disk Space (<drive name>))

Solutions When Viewer Problems Occur

If you encounter problems when you use the Viewer, refer to the following solutions:

Viewer and Video windows

Problem
I cannot use the pan, tilt or zoom feature of the
camera in the video window.
When I click a video window to display the
[Video Window] menu, [Record Now] is gray
(unavailable). But, I can use the feature in
another video window.
When I try to use layouts created by other users,
the [Layouts] menu is not displayed. I cannot
select a layout.
The quality of live or recorded images displayed
in the video window is not good.
None of the cameras will record.
Some cameras do not record.
9
-2
Log
Storage Server
CameraServer <host name>
disconnected(<error
information>)
• Double-click the video window or click [Control] on the [Camera Control] panel
(P. 6-8).
• If images are being played (the title bar of the video window is gray), you cannot
operate the camera. Click [Live] on the timeline and get control of the camera.
Display [<camera name>Properties] for the video window and check on the
[Advanced] tab whether the camera is disabled. If the camera is disabled, click
[Enable Camera]. (P. 3-10).
Layouts saved in the [User Layouts] folder cannot be seen by other users.
To allow all users to access layouts created by a user, the layouts must be created by
a user with administrator permissions and must be saved in the [Shared Layouts]
folder (P. 4-11).
The quality of live or recorded images cannot be changed. The video quality may
depend on the camera settings of the video window. The video quality for the camera
can be increased using the settings on the camera.
• Is the network cable for the server properly connected?
• Has there been a power failure?
• If link lamps on the hub (switching hub) and on the network connector on the
server do not light, there may be a defect in the server's cable, hub (switch), or
network connector.
• Is the power and the network connection for the cameras working?
• Do the cameras reply to a ping?
• Can you view live images on the Viewer for the cameras?
Cause
A network error may have
occurred. Look for the cause of
the error by checking the
Winsock error code recorded in
the Storage Server log (P. 9-7).
• The effective recording rate is
excessively low (below 50%).
• The load on the Storage
Server CPU may be high.
The load from writing recorded
data to the hard disk may be too
high.
Solution
Action
Check the network (hub, cables,
etc.) for any problems and make
sure that the camera is
operating normally.
• Modify the recording
schedule.
• Check the current CPU usage
and terminate any
applications that are a heavy
load on the CPU.
Shorten the maximum storage
period or consider adding a
hard disk. Additionally, try to
modify the recording schedule.