Processor Thermal Solution Performance Assessment; Local Ambient Temperature Measurement Guidelines - Intel E6700 - Core 2 Duo Dual-Core Processor Design Manual

Mechanical design guidelines
Table of Contents

Advertisement

Thermal Metrology
Assume the TDP, as listed in the datasheet, is 100 W and the maximum case
temperature from the thermal profile for 100 W is 67 °C. Assume as well that the
system airflow has been designed such that the local ambient temperature is 38 °C.
Then, the following could be calculated using equation 1 from above:
Ψ
= (T
CA
To determine the required heatsink performance, a heatsink solution provider would
need to determine Ψ
configuration. If the heatsink solution were designed to work with a TIM material
performing at Ψ
the heatsink would be:
Ψ
= Ψ
SA
3.2
Processor Thermal Solution Performance
Assessment
Thermal performance of a heatsink should be assessed using a thermal test vehicle
(TTV) provided by Intel. The TTV is a stable heat source that the user can make
accurate power measurement, whereas processors can introduce additional factors
that can impact test results. In particular, the power level from actual processors
varies significantly, even when running the maximum power application provided by
Intel, due to variances in the manufacturing process. The TTV provides consistent
power and power density for thermal solution characterization and results can be
easily translated to real processor performance. Accurate measurement of the power
dissipated by an actual processor is beyond the scope of this document.
Once the thermal solution is designed and validated with the TTV, it is strongly
recommended to verify functionality of the thermal solution on real processors and on
fully integrated systems. The Intel maximum power application enables steady power
dissipation on a processor to assist in this testing. This maximum power application is
provided by Intel.
3.3
Local Ambient Temperature Measurement
Guidelines
The local ambient temperature T
the processor. For a passive heatsink, T
temperature; for an actively cooled heatsink, it is the temperature of inlet air to the
active cooling fan.
It is worthwhile to determine the local ambient temperature in the chassis around the
processor to understand the effect it may have on the case temperature.
T
is best measured by averaging temperature measurements at multiple locations in
A
the heatsink inlet airflow. This method helps reduce error and eliminate minor spatial
variations in temperature. The following guidelines are meant to enable accurate
determination of the localized air temperature around the processor during system
thermal testing.
Thermal and Mechanical Design Guidelines
− T
) / TDP = (67 – 38) / 100 = 0.29 °C/W
C,
A
performance for the selected TIM and mechanical load
CS
≤ 0.10 °C/W, solving for equation 2 from above, the performance of
CS
− Ψ
= 0.29 − 0.10 = 0.19 °C/W
CA
CS
is the temperature of the ambient air surrounding
A
is defined as the heatsink approach air