Power Supplies; Removing A Power Supply - Dell PowerEdge HX574 Hardware Owner's Manual

Dell server hardware owner's manual
Table of Contents

Advertisement

2 Gently press down on the shroud assembly until it is fully seated. The
upper surface of the shroud should be flush with the fan bays when the
shroud assembly is correctly installed.

Power Supplies

Your system supports two power supplies. The second power supply serves as a
redundant, hot-plug power source.
NOTICE:
The system is only in the redundant mode when two power supplies are
installed and both power supplies are connected to an AC power source. If some
third-party components (such as PCI cards) not tested or supported by Dell are
installed, the power supplies may not be redundant at all input voltages.
NOTICE:
Operating the system with only one power supply installed for extended
periods of time can cause the system to overheat.

Removing a Power Supply

1 Disconnect the power cable from the power source and the power supply
you intend to remove and remove the cables from the cable strain-relief
loop.
2 Press the lever release latch, then open the release lever and slide the power
supply out of the chassis. See Figure 3-6.
NOTE:
interferes with power-supply removal. For information about the cable
management arm, see the system's Rack Installation Guide.
You may have to unlatch and lift the cable management arm if it
Installing System Components
73

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge r905

Table of Contents