Table 1-7. LCD Status Messages (continued)
Line 1
Line 2
Message
Message
E201F
DRAC Config
E2020
CPU Config
E2021
Memory
Population
E2022
POST Fail
E2110
MBE DIMM ##
& ##
E2111
SBE Log
Disable DIMM
##
30
About Your System
Causes
Remote access controller
(RAC) configuration
failure.
CPU configuration
failure.
Incorrect memory
configuration. Memory
population order
incorrect.
General failure after
video.
One of the DIMMs in the
set implicated by "## &
##" has had a memory
multi-bit error (MBE).
The system BIOS has
disabled memory single-
bit error (SBE) logging,
and will not resume
logging further SBEs until
the system is rebooted.
"##" represents the
DIMM implicated by the
BIOS.
Corrective Actions
Check screen for specific
error messages. Ensure
that the RAC card and
cables are properly seated.
See "RAC Card" on
page 86. If problem
persists, see your RAC
documentation.
Check screen for specific
error messages.
Check screen for specific
error messages. See
"Troubleshooting System
Memory" on page 158.
Check screen for specific
error messages.
See "Troubleshooting
System Memory" on
page 158.
See "Troubleshooting
System Memory" on
page 158.