Dell PowerEdge HX574 Hardware Owner's Manual page 28

Dell server hardware owner's manual
Table of Contents

Advertisement

Table 1-7. LCD Status Messages (continued)
Line 1
Line 2
Message
Message
E1812
HDD ##
Removed
E1914
DRAC5 Conn2
Cbl
E1A14
SAS Cable A
E1A15
SAS Cable B
E1A1C
LOM Mezz
Missing
E2010
No Memory
E2011
Mem Config
Err
E2012
Unusable
Memory
28
About Your System
Causes
Specified hard drive has
been removed from the
system.
DRAC 5 cable is missing
or unseated.
SAS cable A is unseated,
missing, or bad.
SAS cable B is unseated,
missing, or bad.
NIC daughter card is
missing.
No memory is installed in
the system.
Memory detected, but is
not configurable. Error
detected during memory
configuration.
Memory is configured,
but not usable. Memory
subsystem failure.
Corrective Actions
Information only.
Reconnect the cable. See
"RAC Card" on page 86.
Check the cable
connection to the SAS
backplane. See "SAS
Backplane Board
Connectors" on page 178.
Check the cable
connection to the SAS
backplane. See "SAS
Backplane Board
Connectors" on page 178.
Install or reseat the NIC
daughter card.
Install memory modules.
See "System Memory" on
page 94.
Check the memory
configuration and
reinstall the memory
modules if necessary. See
"System Memory" on
page 94.
See "Troubleshooting
System Memory" on
page 158.
See "Troubleshooting
System Memory" on
page 158.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge r905

Table of Contents