Position the card so that the card-edge connector aligns with the
b
expansion-card connector.
Insert the card-edge connector firmly into the expansion-card
c
connector until the card is fully seated.
6 Connect the 50-pin management cable and the 44-pin MII cable supplied
with the RAC to the two connectors on the RAC card (see Figure 3-14),
and to the two corresponding connectors on the system board (see
Figure 6-1).
Figure 3-14. RAC Card Connectors
1
1
RJ-45 RAC NIC connector
3
50-pin management cable connector
7 Reinstall the storage controller card.
8 Reconnect all cables to the storage controller card.
9 Close the system. See "Closing the System" on page 68.
10 Reconnect the system and peripherals to their power sources, and turn
them on.
11 Enter the System Setup program and verify that the setting for the Boot
Sequence has changed to reflect the presence of the RAC card. See "Using
the System Setup Program" on page 45.
12 Exit the System Setup program and reboot the system.