Troubleshooting Power Supplies - Dell PowerEdge HX574 Hardware Owner's Manual

Dell server hardware owner's manual
Table of Contents

Advertisement

NOTE:
If the system is turned off for long periods of time (for weeks or months), the
NVRAM may lose its system configuration information. This situation is caused by a
defective battery.
Action
1 Re-enter the time and date through the System Setup program. See "Using
the System Setup Program" on page 45.
2 Turn off the system and disconnect it from the electrical outlet for at least
one hour.
3 Reconnect the system to the electrical outlet and turn on the system.
4 Enter the System Setup program.
If the date and time are not correct in the System Setup program, replace
the battery. See "System Battery" on page 117.
If the problem is not resolved by replacing the battery, see "Getting Help"
on page 181.
NOTE:
Some software may cause the system time to speed up or slow down. If the
system seems to operate normally except for the time kept in the System Setup
program, the problem may be caused by software rather than by a defective
battery.

Troubleshooting Power Supplies

Problem
System-status indicators are amber.
Power-supply fault indicators are amber.
Front-panel status LCD indicates a problem with the power supplies.
Action
1 Locate the faulty power supply.
The power supply's fault indicator is lit. See "Power Indicator Codes" on
page 19.
156
Troubleshooting Your System

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge r905

Table of Contents